Show simple item record

dc.contributor.authorZuhaib, Sheikh
dc.contributor.authorManton, Richard
dc.contributor.authorGriffin, Corey
dc.contributor.authorHajdukiewicz, Magdalena
dc.contributor.authorKeane, Marcus M.
dc.contributor.authorGoggins, Jamie
dc.date.accessioned2019-08-21T10:53:12Z
dc.date.issued2018-05-07
dc.identifier.citationZuhaib, Sheikh, Manton, Richard, Griffin, Corey, Hajdukiewicz, Magdalena, Keane, Marcus M., & Goggins, Jamie. (2018). An Indoor Environmental Quality (IEQ) assessment of a partially-retrofitted university building. Building and Environment, 139, 69-85. doi: https://doi.org/10.1016/j.buildenv.2018.05.001en_IE
dc.identifier.issn1873-684X
dc.identifier.urihttp://hdl.handle.net/10379/15336
dc.description.abstractAchieving standards-based Indoor Environmental Quality (IEQ) in existing buildings is growing steadily due to the strong demand for deep retrofits in Europe. Existing non-domestic buildings pose challenges mainly due to occupancy patterns, lack of personal control over comfort and outdated building structures. Renovations of many post-war non-domestic buildings (>35 years old) have faced technical and financial challenges. Consequently, these buildings are often only partially retrofitted, which are often ad-hoc in nature. This paper describes the evaluation process of indoor environmental conditions in a partially-retrofitted university building in Galway (Ireland) originally built during the 1970s and partially retrofit in 2005. The research assesses criteria outlined in EN 15251 and draws on methods from ASHRAE 55 and CBE IEQ survey. Occupant surveys complemented by physical measurements were used to assess the compliance of IEQ parameters for thermal, visual and acoustic comfort and indoor air quality. The relationship between the performance of the building envelope and occupant comfort is described across retrofitted and non-retrofitted zones of the building. The results suggest that ad-hoc retrofitting of the façade did not make any significant difference to IEQ and occupants continued to adapt personally to the existing conditions. Their preferred satisfaction levels in the survey were lower than the measured thermal sensation. It is recommended that future retrofits are adequately planned and optimised to improve both IEQ and energy performance. A whole building retrofit approach must balance and include factors such as human health, building fabric and energy savings to avoid the pitfalls of current practice.en_IE
dc.description.sponsorshipThe authors would like to acknowledge financial support from Science Foundation Ireland (Grant No. 13/CDA/2200). The authors would also like to thank all the participants of survey from the field study building and the Buildings & Estates Office at NUI Galway for facilitating this study.en_IE
dc.formatapplication/pdfen_IE
dc.language.isoenen_IE
dc.publisherElsevieren_IE
dc.relation.ispartofBuilding And Environmenten
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Ireland
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/ie/
dc.subjectStandards for retrofitsen_IE
dc.subjectField studyen_IE
dc.subjectIndooren_IE
dc.subjectEnvironmental Qualityen_IE
dc.subjectThermal comforten_IE
dc.subjectIndoor air qualityen_IE
dc.subjectOccupant surveyen_IE
dc.titleAn Indoor Environmental Quality (IEQ) assessment of a partially-retrofitted university buildingen_IE
dc.typeArticleen_IE
dc.date.updated2019-07-29T15:04:47Z
dc.identifier.doi10.1016/j.buildenv.2018.05.001
dc.local.publishedsourcehttps://doi.org/10.1016/j.buildenv.2018.05.001en_IE
dc.description.peer-reviewedpeer-reviewed
dc.contributor.funderScience Foundation Irelanden_IE
dc.description.embargo2020-05-07
dc.internal.rssid15356052
dc.local.contactMagdalena Hajdukiewicz, Civil Engineering Eng 1023, Engineering Building, College Of Eng & Informatics, Nui Galway. Email: magdalena.hajdukiewicz@nuigalway.ie
dc.local.copyrightcheckedYes
dc.local.versionACCEPTED
dcterms.projectinfo:eu-repo/grantAgreement/SFI/SFI Career Development Award/13/CDA/2200/IE/Achieving nearly zero energy buildings - A life cycle assessment approach to retrofitting existing buildings (acronym: nZEB-RETROFIT)/en_IE
nui.item.downloads1083


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Ireland
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Ireland