Search
Now showing items 1-4 of 4
Comparison of macintosh, truview evo2(r), glidescope(r), and airwayscope(r) laryngoscope use in patients with cervical spine immobilization
(Oxford University Press (OUP), 2008-08-08)
Background. The purpose of this study was to evaluate the effectiveness of the Pentax AWS (R), Glidescope (R), and the Truview EVO2 (R), in comparison with the Macintosh laryngoscope, when performing tracheal intubation ...
Tracheal intubation in patients with cervical spine immobilization: a comparison of the airwayscope®, lma ctrach®, and the macintosh laryngoscopes
(Oxford University Press (OUP), 2009-03-31)
The purpose of this study was to evaluate the effectiveness of the Pentax AWS (R), and the LMA CTrach (R), in comparison with the Macintosh laryngoscope, when performing tracheal intubation in patients with neck immobilization ...
Randomized controlled trial of the pentax aws(r), glidescope(r), and macintosh laryngoscopes in predicted difficult intubation
(Oxford University Press (OUP), 2009-09-24)
Background. The purpose of this study was to determine the potential for the Pentax AWS (R) and the Glidescope (R) to reduce the difficulty of tracheal intubation in patients at increased risk for difficult tracheal ...
Comparison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model
(Oxford University Press (OUP), 2010-10-30)
Background. Emergency cricothyroidotomy is a potentially life-saving procedure in the 'cannot intubate cannot ventilate (CICV)' scenario. Although surgical cricothyroidotomy remains the technique recommended in many 'CICV' ...