Show simple item record

dc.contributor.authorReddan, D. N.
dc.date.accessioned2018-08-24T08:26:15Z
dc.date.available2018-08-24T08:26:15Z
dc.date.issued2005-04-20
dc.identifier.citationReddan, D. N. (2005). Intradialytic blood volume monitoring in ambulatory hemodialysis patients: a randomized trial. Journal of the American Society of Nephrology 16 (7), 2162-2169
dc.identifier.issn1046-6673,1533-3450
dc.identifier.urihttp://hdl.handle.net/10379/9804
dc.description.abstractComplications related to inadequate volume management are common during hemodialysis. This trial tested the hypothesis that availability of an intradialytic blood volume monitoring (IBVM) device improves fluid removal, reducing morbidity. A six-center, randomized trial with 6 mo of intervention comparing IBVM using Crit-Line versus conventional clinical monitoring was conducted. The average rate of non-access-related hospitalizations was compared across treatment groups using Poisson regression. Mortality analysis used the Kaplan Meier method. A total of 227 patients were randomized to Crit-Line, and 216 were randomized to conventional monitoring. Both groups had similar baseline characteristics. During the study, no differences in weight, BP, or number of dialysis-related complications were observed. There were 120 and 81 non-access-related hospitalizations in the Crit-Line and conventional monitoring groups. The adjusted risk ratio for non-access-related and access-related hospitalization was 1.61 (95% confidence interval 1.15 to 2.25; P = 0.01) and 1.52 (95% confidence interval 1.02 to 2.28; P = 0.04) for the Crit-Line monitoring group. Mortality was 8.7% in the Crit-Line monitoring group and 3.3% in the conventional group (P = 0.021). Standardized mortality ratios comparing the Crit-Line and conventional monitoring groups to the prevalent hemodialysis population were 0.77 (NS) and 0.26 (P < 0.001). Hospitalization rates were 1.51 and 1.03 events/yr in the Crit-Line and standard monitoring groups, compared with 2.01 for the prevalent hemodialysis population. IBVM was associated with higher nonvascular and vascular access-related hospitalizations and mortality compared with conventional monitoring. The atypically low hospitalization and mortality rates for the conventional monitoring group suggest that these findings should be generalized to the US hemodialysis population with caution.
dc.publisherAmerican Society of Nephrology (ASN)
dc.relation.ispartofJournal of the American Society of Nephrology
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Ireland
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/ie/
dc.subjectright heart catheterization
dc.subjecthematocrit
dc.subjectvalidity
dc.titleIntradialytic blood volume monitoring in ambulatory hemodialysis patients: a randomized trial
dc.typeArticle
dc.identifier.doi10.1681/asn.2004121053
dc.local.publishedsourcehttp://jasn.asnjournals.org/content/16/7/2162.full.pdf
nui.item.downloads0


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Ireland
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Ireland