Show simple item record

dc.contributor.authorMaharaj, C. H.
dc.contributor.authorHiggins, B. D.
dc.contributor.authorHarte, B. H.
dc.contributor.authorLaffey, J. G.
dc.date.accessioned2018-08-24T08:25:31Z
dc.date.available2018-08-24T08:25:31Z
dc.date.issued2006-05-01
dc.identifier.citationMaharaj, C. H. Higgins, B. D.; Harte, B. H.; Laffey, J. G. (2006). Evaluation of intubation using the airtraqr or macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy - a manikin study*. Anaesthesia 61 (5), 469-477
dc.identifier.issn0003-2409,1365-2044
dc.identifier.urihttp://hdl.handle.net/10379/9472
dc.description.abstractThe Airtraq (R) Laryngoscope is a novel intubation device which allows visualisation of the vocal cords without alignment of the oral, pharyngeal and tracheal axes. We compared the Airtraq (R) with the Macintosh laryngoscope in simulated easy and difficult laryngoscopy. Twenty-five anaesthetists were allowed up to three attempts to intubate the trachea in each of three laryngoscopy scenarios using a Laerdal (R) Intubation Trainer followed by five scenarios using a Laerdal SimMan (R) Manikin. Each anaesthetist then performed tracheal intubation of the normal airway a second time to characterise the learning curve. In the simulated easy laryngoscopy scenarios, there was no difference between the Airtraq (R) and the Macintosh in success of tracheal intubation. The time taken to intubate at the end of the protocol was significantly lower using the Airtraq (R) (9.5 (6.7) vs. 14.2 (7.4) s), demonstrating a rapid acquisition of skills. In the simulated difficult laryngoscopy scenarios, the Airtraq (R) was more successful in achieving tracheal intubation, required less time to intubate successfully, caused less dental trauma, and was considered by the anaesthetists to be easier to use.
dc.publisherWiley-Blackwell
dc.relation.ispartofAnaesthesia
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Ireland
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/ie/
dc.subjectcreutzfeldt-jakob-disease
dc.subjectclosed claims analysis
dc.subjecttracheal intubation
dc.subjectairway management
dc.subjectbullard laryngoscope
dc.subjectlearning-curve
dc.subjectlaryngeal mask
dc.subjectmultiple-use
dc.subjectblades
dc.subjectanesthesia
dc.titleEvaluation of intubation using the airtraqr or macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy - a manikin study*
dc.typeArticle
dc.identifier.doi10.1111/j.1365-2044.2006.04547.x
dc.local.publishedsourcehttp://onlinelibrary.wiley.com/doi/10.1111/j.1365-2044.2006.04547.x/pdf
nui.item.downloads0


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Ireland
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Ireland