Show simple item record

dc.contributor.authorMcDermott, Barry
dc.contributor.authorPorter, Emily
dc.contributor.authorJones, Marggie
dc.contributor.authorMcGinley, Brian
dc.contributor.authorO'Halloran, Martin
dc.date.accessioned2018-08-20T12:01:57Z
dc.date.available2018-08-20T12:01:57Z
dc.date.issued2018-01-26
dc.identifier.citationMcDermott, Barry, Porter, Emily, Jones, Marggie, McGinley, Brian, & O'Halloran, Martin. (2018). Electrical impedance tomography with exploitation of symmetry. Paper presented at the Bioengineering in Ireland 2018, 24th Annual Conference of the Section of Bioengineering of the Royal Academy of Medicine in Ireland (BinI 2018), Dublin City University, 26-27 January.en_IE
dc.identifier.urihttp://hdl.handle.net/10379/7517
dc.description.abstractElectrical Impedance Tomography (EIT) is an imaging technique involving an electrode array positioned around the area of interest. Alternating current is injected, and voltage measured, between electrode pairs in a prescribed pattern to produce a measurement set. This set is then processed to generate an image of the area. EIT has several potential biomedical applications including thoracic and neural imaging. Different EIT variants exist with most success being in the production of time difference images. Generation of absolute images (i.e., images generated from a single measurement time) is challenging due to the sensitivity of EIT to errors such as those of electrode placement. This challenge makes imaging of static or very slowly changing scenes, such as those featuring a tumour or an established haemorrhage, very difficult with EIT. In this work, the natural symmetry of an anatomy, such as the sagittal symmetry in the human head, is used to create a difference image without a time change. Measurements are taken from both mirror images of the scene with the difference of the sets processed to produce an image highlighting any deviations in symmetry. This proposed technique allows detection of unilateral pathologies, such as, for example, a bleed in stroke patients.en_IE
dc.formatapplication/pdfen_IE
dc.language.isoenen_IE
dc.publisherBioengineering in Ireland 2018en_IE
dc.relation.ispartofBioengineering in Ireland 2018en
dc.subjectIrelanden_IE
dc.subjectBioengineeringen_IE
dc.subjectElectrical impedance tomographyen_IE
dc.titleElectrical impedance tomography with exploitation of symmetryen_IE
dc.typeConference Paperen_IE
dc.date.updated2018-08-15T17:40:46Z
dc.local.publishedsourcehttps://binirl.com/proceedings/en_IE
dc.description.peer-reviewednon-peer-reviewed
dc.internal.rssid14792738
dc.local.contactBarry Mc Dermott, Translational Medical Device Lab, , 2nd Floor Lambe Translational Research Facility,, University College Hospital, , Galway. - Email: b.mcdermott3@nuigalway.ie
dc.local.copyrightcheckedYes
dc.local.versionPUBLISHED
nui.item.downloads13


Files in this item

Attribution-NonCommercial-NoDerivs 3.0 Ireland
This item is available under the Attribution-NonCommercial-NoDerivs 3.0 Ireland. No item may be reproduced for commercial purposes. Please refer to the publisher's URL where this is made available, or to notes contained in the item itself. Other terms may apply.

The following license files are associated with this item:

Thumbnail

This item appears in the following Collection(s)

Show simple item record