dc.identifier.citationCallery, O., Healy, M. G., Rognard, F., Barthelemy, L., & Brennan, R. B. (2016). Evaluating the long-term performance of low-cost adsorbents using small-scale adsorption column experiments. Water Research, 101, 429-440. doi: http://dx.doi.org/10.1016/j.watres.2016.05.093en_IE
dc.identifier.issn1879-2448
dc.identifier.urihttp://hdl.handle.net/10379/6673
dc.description.abstractThis study investigated a novel method of predicting the long-term phosphorus removal performance of large-scale adsorption filters, using data derived from short-term, small-scale column experiments. The filter media investigated were low-cost adsorbents such as aluminum sulfate drinking water treatment residual, ferric sulfate drinking water treatment residual, and fine and coarse crushed concretes. Small-bore adsorption columns were loaded with synthetic wastewater, and treated column effluent volume was plotted against the mass of phosphorus adsorbed per unit mass of filter media. It was observed that the curve described by the data strongly resembled that of a standard adsorption isotherm created from batch adsorption data. Consequently, it was hypothesized that an equation following the form of the Freundlich isotherm would describe the relationship between filter loading and media saturation. Moreover, the relationship between filter loading and effluent concentration could also be derived from this equation. The proposed model was demonstrated to accurately predict the performance of large-scale adsorption filters over a period of up to three months with a very high degree of accuracy. Furthermore, the coefficients necessary to produce said model could be determined from just 24 hours of small-scale experimental data.en_IE
dc.formatapplication/pdfen_IE
dc.language.isoenen_IE
dc.publisherElsevieren_IE
dc.relation.ispartofWater Researchen
dc.subjectAdsorptionen_IE
dc.subjectColumnen_IE
dc.subjectPhosphorusen_IE
dc.subjectLow-cost adsorbenten_IE
dc.subjectModelingen_IE
dc.titleEvaluating long-term performance of low-cost adsorbents using small-scale adsorption column experimentsen_IE
dc.typeArticleen_IE
dc.date.updated2017-07-11T15:15:40Z
dc.identifier.doi10.1016/j.watres.2016.05.093
dc.local.publishedsourcehttps://doi.org/10.1016/j.watres.2016.05.093en_IE
dc.description.peer-reviewedpeer-reviewed
dc.contributor.funder|~|6201984|~|
dc.internal.rssid11060875
dc.local.contactMark Healy, Room Eng-1038, Civil Engineering, Col Of Engineering & Informatics, Nui Galway. 5364 Email: mark.healy@nuigalway.ie
dc.local.copyrightcheckedNo
dc.local.versionPUBLISHED
nui.item.downloads285


Files in this item

Attribution-NonCommercial-NoDerivs 3.0 Ireland
This item is available under the Attribution-NonCommercial-NoDerivs 3.0 Ireland. No item may be reproduced for commercial purposes. Please refer to the publisher's URL where this is made available, or to notes contained in the item itself. Other terms may apply.

The following license files are associated with this item:

Thumbnail

This item appears in the following Collection(s)

Show simple item record