Show simple item record

dc.contributor.authorDestrade, Michel
dc.contributor.editorIEEE
dc.date.accessioned2016-06-03T14:12:19Z
dc.date.available2016-06-03T14:12:19Z
dc.date.issued2006
dc.identifier.citationJ. Mazeyrat, O. Romain, P. Garda, E. Flecher, M. Karouia, P. Leprince, P.-Y. Lagree, M. Destrade (2006) Wireless communicative stent for follow-up of abdominal aortic aneurysm . In: IEEE eds. 2006 IEEE Biomedical Circuits and Systems Conference (IEEE-BioCAS 2006) London, 29/11/2006- 01/12/2006en_IE
dc.identifier.issn2163-4025
dc.identifier.urihttp://hdl.handle.net/10379/5857
dc.description.abstractAn abdominal aortic aneurysm (AAA) is a dilatation of the aorta at the abdominal level, which rupture is a life threatening complication. Recent treatment of AAA consists in endovascular treatment with covered stent grafts. Despite improving devices, this treatment is still associated with close to 25% of failure related to persisting pressure into the excluded aneurismal sac. The follow-up becomes thus crucial and demands frequent examinations (CT-scan, IRM) which are not so liable given the complications. In order to evaluate the post-operative period of an AAA treatment, we designed a communicative stent, comprising of an integrated pressure sensor. This paper presents the conception of a communicative sensor, the elaboration of a numerical model, and the development of an experimental testbench constituting the aortic flux across an AAA and allowing the optimization and validation of the measurement principle.en_IE
dc.formatapplication/pdfen_IE
dc.language.isoenen_IE
dc.publisherIEEEen_IE
dc.relation.ispartof2006 IEEE Biomedical Circuits and Systems Conference (IEEE-BioCAS 2006)en
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Ireland
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/ie/
dc.subjectAbdominal aortic aneurysmen_IE
dc.subjectAneurismal sacen_IE
dc.subjectAortic dilationen_IE
dc.subjectAortic fluxen_IE
dc.subjectCommunicative sensoren_IE
dc.subjectEndovascular treatmenten_IE
dc.subjectIntegrated pressure sensoren_IE
dc.subjectRuptureen_IE
dc.subjectStent graftsen_IE
dc.subjectWireless communicative stenten_IE
dc.titleWireless communicative stent for follow-up of abdominal aortic aneurysm,en_IE
dc.typeConference Paperen_IE
dc.date.updated2016-06-03T07:57:21Z
dc.identifier.doi10.1109/BIOCAS.2006.4600352
dc.local.publishedsourcehttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=4600352en_IE
dc.description.peer-reviewedpeer-reviewed
dc.contributor.funder|~|
dc.internal.rssid10406881
dc.local.contactMichel Destrade, Room Adb-1002, Áras De Brun, School Of Mathematics, Nui Galway. 2344 Email: michel.destrade@nuigalway.ie
dc.local.copyrightcheckedNo
dc.local.versionPUBLISHED
nui.item.downloads378


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Ireland
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Ireland