dc.contributor.author | Ni Annaidh, Aisling | |
dc.contributor.author | Ottenio, M. | |
dc.contributor.author | Bruyere, K. | |
dc.contributor.author | Destrade, Michel | |
dc.contributor.author | Gilchrist, Michael D. | |
dc.contributor.editor | Springer | |
dc.date.accessioned | 2016-04-27T11:21:30Z | |
dc.date.available | 2016-04-27T11:21:30Z | |
dc.date.issued | 2010 | |
dc.identifier.citation | Annaidh, A. Ní, Ottenio, M., Bruyère, K., Destrade, M., & Gilchrist, M. D. (2010). Mechanical Properties of Excised Human Skin. In C. T. Lim & J. C. H. Goh (Eds.), 6th World Congress of Biomechanics (WCB 2010). August 1-6, 2010 Singapore: In Conjunction with 14th International Conference on Biomedical Engineering (ICBME) and 5th Asia Pacific Conference on Biomechanics (APBiomech) (pp. 1000-1003). Berlin, Heidelberg: Springer Berlin Heidelberg. | en_IE |
dc.identifier.isbn | 978-3-642-14515-5 | |
dc.identifier.issn | 1680-0737 | |
dc.identifier.uri | http://hdl.handle.net/10379/5722 | |
dc.description.abstract | In this study we have investigated in influence of
location, gender and orientation on the deformation characteristics
of 55 samples of human excised skin. Uniaxial tensile
tests were carried out at a strain rate of 0.012s-1 on excised
human skin from the back. The deformation characteristics of
skin (Ultimate Tensile Strength (P<0.0001), Failure Strain
(P=0.0177), Young s Modulus (P<0.0076), Initial Slope
(P=0.0375) and Strain Energy (P=0.0101)) were found to be
dependent upon the orientation of specimens with respect to
the Langer s Lines. The location of specimens on the back was
also found to have a significant effect on the Ultimate Tensile
Strength (P =0.0002), the Young s Modulus (P=0.0017) and the
Strain Energy (P=0.005). | en_IE |
dc.description.sponsorship | Irish Research Council for Science and Engineering Technology and the Irish Department of Justice Equality and Law Reform | en_IE |
dc.format | application/pdf | en_IE |
dc.language.iso | en | en_IE |
dc.publisher | Springer Verlag | en_IE |
dc.relation.ispartof | 6th World Congress of Biomechanics (WCB 2010). | en |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Ireland | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/3.0/ie/ | |
dc.subject | Skin | en_IE |
dc.subject | Langer's lines | en_IE |
dc.subject | Histology | en_IE |
dc.subject | Mathematics | en_IE |
dc.title | Mechanical properties of excised human skin | en_IE |
dc.type | Conference Paper | en_IE |
dc.date.updated | 2015-10-09T08:10:49Z | |
dc.identifier.doi | 10.1007/978-3-642-14515-5_255 | |
dc.local.publishedsource | http://link.springer.com/chapter/10.1007/978-3-642-14515-5_255 | en_IE |
dc.description.peer-reviewed | peer-reviewed | |
dc.contributor.funder | |~|6201984|~| | |
dc.internal.rssid | 9307424 | |
dc.local.contact | Michel Destrade, Room Adb-1002, Áras De Brun, School Of Mathematics, Nui Galway. 2344 Email: michel.destrade@nuigalway.ie | |
dc.local.copyrightchecked | No | |
dc.local.version | PUBLISHED | |
nui.item.downloads | 339 | |