Show simple item record

dc.contributor.authorGoggins, Jamie
dc.contributor.authorKeane, Terasa
dc.contributor.authorKelly, Alan
dc.date.accessioned2013-11-20T17:20:34Z
dc.date.available2013-11-20T17:20:34Z
dc.date.issued2010
dc.identifier.citationGoggins, J,Keane, T,Kelly, A (2010) 'The assessment of embodied energy in typical reinforced concrete building structures in Ireland'. Energy And Buildings, 42 :735-744.en_US
dc.identifier.urihttp://hdl.handle.net/10379/3826
dc.description.abstractThis paper demonstrates that by understanding how energy is consumed in the manufacturing of reinforced concrete, designers can significantly reduce the overall embodied energy of structures. Embodied energy of products can vary from country to country. Therefore, to accurately estimate the embodied energy of reinforced concrete structures, data specific to the country where they are being constructed must be used. This paper presents the assessment of embodied energy in typical RC building structures in Ireland.The most common methods used to calculate EE are evaluated in this paper and the most suitable method was applied to reinforced concrete. The EE of a typical 30 MPa concrete mix in Ireland is calculated to be 1.08 MJ/kg. Notably cement is credited with 68% of the total EE. The major contributors of energy consumption are identified, which should aid to minimise energy consumption and optimise efficiency.A case study is presented which compares the EE of a typical reinforced concrete structure in Ireland using two concrete mix designs. The first uses Ordinary Portland Cement, while the second uses GGBS replacing half of the cement content. As expected, the EE of the GGBS mix is significantly lower (30%) than that of its counterpart. (C) 2009 Elsevier B.V. All rights reserved.en_US
dc.formatapplication/pdfen_US
dc.language.isoenen_US
dc.relation.ispartofEnergy And Buildingsen
dc.subjectEmbodied energyen_US
dc.subjectSustainabilityen_US
dc.subjectStructural designen_US
dc.subjectConcreteen_US
dc.titleThe assessment of embodied energy in typical reinforced concrete building structures in Irelanden_US
dc.typeArticleen_US
dc.date.updated2013-09-26T11:23:35Z
dc.identifier.doiDOI 10.1016/j.enbuild.2009.11.013
dc.local.publishedsourcehttp://dx.doi.org/10.1016/j.enbuild.2009.11.013en_US
dc.description.peer-reviewedpeer-reviewed
dc.contributor.funder|~|
dc.internal.rssid1336132
dc.local.contactJamie Goggins, Civil Engineering Department, Nui Galway. 2609 Email: jamie.goggins@nuigalway.ie
dc.local.copyrightcheckedYes
dc.local.versionACCEPTED
nui.item.downloads964


Files in this item

Attribution-NonCommercial-NoDerivs 3.0 Ireland
This item is available under the Attribution-NonCommercial-NoDerivs 3.0 Ireland. No item may be reproduced for commercial purposes. Please refer to the publisher's URL where this is made available, or to notes contained in the item itself. Other terms may apply.

The following license files are associated with this item:

Thumbnail

This item appears in the following Collection(s)

Show simple item record