Show simple item record

dc.contributor.advisorMcHugh, Peter
dc.contributor.authorGrogan, James A.
dc.date.accessioned2013-10-15T12:27:10Z
dc.date.available2013-10-15T12:27:10Z
dc.date.issued2012-09-13
dc.identifier.urihttp://hdl.handle.net/10379/3744
dc.description.abstractDevelopments in metallic coronary stents are toward permanent devices with thinner struts and bioabsorbable devices. To facilitate the development of these promising technologies an improved understanding of thin-strut and bioabsorbable stent mechanical performance is important. The work presented in this thesis uses computational mechanics to investigate the mechanical performance of corroding bioabsorbable metal stents and computational micromechanics to investigate the performance of thin metallic struts undergoing large plastic deformation. The short-term mechanical performance of stents consisting of a range of bioabsorbable and permanent metals is first investigated using typical stent modelling approaches. It is found that devices consisting of bioabsorbable metals can match the short-term scaffolding performance of permanent stents, however the former has a greater risk of fracture. The mechanical performance of permanent and bioabsorbable stent struts undergoing large deformations is then investigated in more detail, using micromechanical analyses based on crystal plasticity theory. Lower limits on suitable strut thicknesses for bioabsorbable and permanent stents are identified, based on predictions of microstructure-dependent ductility size effects. A corrosion model is developed for bioabsorbable metal stents and is calibrated and validated based on immersion experiments on thin bioabsorbable alloy foils. The model is used to predict the scaffolding performance of stents undergoing corrosion in the body. It is found that the form of corrosion undergone by the device in the body has a strong influence on scaffolding performance. In particular, it is predicted that experimentally observed localized corrosion leads to a significant decrease in scaffolding duration relative to an ideal uniform corrosion behaviour, pointing to recommendations for future alloy development for such applications.en_US
dc.subjectCoronary Stenten_US
dc.subjectFinite Element Analysisen_US
dc.subjectBioabsorbableen_US
dc.titleThe Mechanical Performance of Permanent and Bioabsorbable Metal Stentsen_US
dc.typeThesisen_US
dc.contributor.funderIrish Research Councilen_US
dc.local.noteThe mechanical performance of next generation coronary stents is investigated using computer simulation methods. Micromechanics techniques are used to investigate size effects in microscale stent struts and to recommend minimum stent strut thicknesses. Corrosion models are developed to assess and improve the scaffolding performance of absorbable metal stents.en_US
dc.local.finalYesen_US
nui.item.downloads2548


Files in this item

Attribution-NonCommercial-NoDerivs 3.0 Ireland
This item is available under the Attribution-NonCommercial-NoDerivs 3.0 Ireland. No item may be reproduced for commercial purposes. Please refer to the publisher's URL where this is made available, or to notes contained in the item itself. Other terms may apply.

The following license files are associated with this item:

Thumbnail

This item appears in the following Collection(s)

Show simple item record