Show simple item record

dc.contributor.authorSultan, Sherif
dc.contributor.authorHynes, Niamh
dc.date.accessioned2018-09-20T16:25:54Z
dc.date.available2018-09-20T16:25:54Z
dc.date.issued2015-04-04
dc.identifier.citationSultan, Sherif; Hynes, Niamh (2015). Multilayer flow modulator stent technology: a treatment revolution for us patients?. Expert Review of Medical Devices 12 (3), 217-221
dc.identifier.issn1743-4440,1745-2422
dc.identifier.urihttp://hdl.handle.net/10379/14061
dc.description.abstractThoracoabdominal aortic repair is a high-risk procedure in most experienced centers, not only because of anatomical complexity but also due to the fragility of the patients in whom these aneurysms occur. Such repairs are complex, time-consuming and impose a systemic injury upon the patients, regardless of whether the repair is performed by open surgery or via a fenestrated/branched technique. The substantive risks associated with such repairs include death, dialysis and paralysis. The multilayer flow modulator (MFM) is a disruptive technology which promises a minimally invasive reproducible treatment option, with clinical results demonstrating physiological modulation of the aortic sac with abolition of spinal injury. The mode of action of MFM forces us to completely rethink aneurysm pathogenesis and, consequently, it has been met with much cynicism. We aim to uncloak some of the mystery surrounding the MFM, clarify its mode of action and explore the truth behind its clinical effectiveness.
dc.publisherInforma UK Limited
dc.relation.ispartofExpert Review of Medical Devices
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Ireland
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/ie/
dc.subjectaortic dissection
dc.subjectdisruptive technology
dc.subjecthemodynamics
dc.subjectmultilayer flow modulator
dc.subjectthoracoabdominal aortic aneurysm
dc.subjectabdominal aortic-aneurysms
dc.subjectendovascular repair
dc.subjectthoracoabdominal aneurysms
dc.subjectpressure measurements
dc.subjectsac pressure
dc.subjectrupture risk
dc.subjectwall stress
dc.subjectpathologies
dc.subjectendoleaks
dc.subjectdiameter
dc.titleMultilayer flow modulator stent technology: a treatment revolution for us patients?
dc.typeArticle
dc.identifier.doi10.1586/17434440.2015.1030339
dc.local.publishedsourcehttp://www.tandfonline.com/doi/pdf/10.1586/17434440.2015.1030339?needAccess=true
nui.item.downloads0


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Ireland
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Ireland