Show simple item record

dc.contributor.authorBarrett, Harrison H
dc.contributor.authorKupinski, Matthew A
dc.contributor.authorMüeller, Stefan
dc.contributor.authorHalpern, Howard J
dc.contributor.authorMorris, John C
dc.contributor.authorDwyer, Roisin
dc.date.accessioned2018-09-20T16:00:35Z
dc.date.available2018-09-20T16:00:35Z
dc.date.issued2013-11-07
dc.identifier.citationBarrett, Harrison H; Kupinski, Matthew A; Müeller, Stefan; Halpern, Howard J; Morris, John C; Dwyer, Roisin (2013). Objective assessment of image quality vi: imaging in radiation therapy. Physics in Medicine and Biology 58 (22), 8197-8213
dc.identifier.issn0031-9155,1361-6560
dc.identifier.urihttp://hdl.handle.net/10379/10362
dc.description.abstractEarlier work on objective assessment of image quality (OAIQ) focused largely on estimation or classification tasks in which the desired outcome of imaging is accurate diagnosis. This paper develops a general framework for assessing imaging quality on the basis of therapeutic outcomes rather than diagnostic performance. By analogy to receiver operating characteristic (ROC) curves and their variants as used in diagnostic OAIQ, the method proposed here utilizes the therapy operating characteristic or TOC curves, which are plots of the probability of tumor control versus the probability of normal-tissue complications as the overall dose level of a radiotherapy treatment is varied. The proposed figure of merit is the area under the TOC curve, denoted AUTOC. This paper reviews an earlier exposition of the theory of TOC and AUTOC, which was specific to the assessment of image-segmentation algorithms, and extends it to other applications of imaging in external-beam radiation treatment as well as in treatment with internal radioactive sources. For each application, a methodology for computing the TOC is presented. A key difference between ROC and TOC is that the latter can be defined for a single patient rather than a population of patients.
dc.publisherIOP Publishing
dc.relation.ispartofPhysics in Medicine and Biology
dc.subjectsodium-iodide symporter
dc.subjectgenetically targeted radiotherapy
dc.subjectelectron-paramagnetic-resonance
dc.subjectprostate-cancer
dc.subjectideal observers
dc.subjectbreast-cancer
dc.subjectoptimization
dc.subjectmodels
dc.subjectcarcinoma
dc.subjectimrt
dc.titleObjective assessment of image quality vi: imaging in radiation therapy
dc.typeArticle
dc.identifier.doi10.1088/0031-9155/58/22/8197
dc.local.publishedsourcehttp://iopscience.iop.org/article/10.1088/0031-9155/58/22/8197/pdf
nui.item.downloads0


Files in this item

This item appears in the following Collection(s)

Show simple item record