Browsing by Subject "truview evo2(r)"
Now showing items 1-7 of 7
-
A comparison of the glidescope®, pentax aws®, and macintosh laryngoscopes when used by novice personnel: a manikin study
(Springer Nature, 2009-08-05)Purpose Direct laryngoscopic tracheal intubation is a potentially lifesaving procedure, but a difficult skill to acquire and maintain. The consequences of poorly performed intubation attempts are potentially severe. The ... -
Comparison of the c-mac® videolaryngoscope with the macintosh, glidescope®, and airtraq® laryngoscopes in easy and difficult laryngoscopy scenarios in manikins
(Wiley-Blackwell, 2010-03-19)P>The C-MAC (R) comprises a Macintosh blade connected to a video unit. The familiarity of the Macintosh blade, and the ability to use the C-MAC as a direct or indirect laryngoscope, may be advantageous. We wished ... -
Comparison of the c-mac®, airtraq®, and macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization
(Oxford University Press (OUP), 2011-05-17)Background. We aimed at comparing the performance of the C-MAC (R), Airtraq (R), and Macintosh laryngoscopes when performing tracheal intubation in patients undergoing neck immobilization using manual inline axial cervical ... -
Determination of the optimal stylet strategy for the c-mac®videolaryngoscope
(Wiley-Blackwell, 2010-03-01)The C-MAC (R) videolaryngoscope is a novel intubation device that incorporates a camera system at the end of its blade, thereby facilitating obtaining a view of the glottis without alignment of the oral, pharyngeal and ... -
Determination of the utility of the intubation difficulty scale for use with indirect laryngoscopes
(Wiley-Blackwell, 2011-10-04)The purpose of this study was to determine whether the Intubation Difficulty Scale is meaningful when used with indirect laryngoscopes. Data were analysed from previously published clinical trials from our group that ... -
Randomized controlled trial of the pentax aws(r), glidescope(r), and macintosh laryngoscopes in predicted difficult intubation
(Oxford University Press (OUP), 2009-09-24)Background. The purpose of this study was to determine the potential for the Pentax AWS (R) and the Glidescope (R) to reduce the difficulty of tracheal intubation in patients at increased risk for difficult tracheal ... -
Tracheal intubation in patients with cervical spine immobilization: a comparison of the airwayscope®, lma ctrach®, and the macintosh laryngoscopes
(Oxford University Press (OUP), 2009-03-31)The purpose of this study was to evaluate the effectiveness of the Pentax AWS (R), and the LMA CTrach (R), in comparison with the Macintosh laryngoscope, when performing tracheal intubation in patients with neck immobilization ...